The HI98162 is a rugged, waterproof, Foodcare portable pH meter that measures pH and temperature using the specialized FC1013 probe for milk products. This professional, waterproof meter complies with IP67 standards. The HI98162 is supplied with all necessary accessories to perform a pH/temperature measurement packaged into a durable thermoformed carrying case that holds the meters, probes and calibration buffers securely in place.
Portable, perfect for the production floor. Easily carry this meter around and test where you need to.
Multiple language options are available, users can switch how messages are displayed.
pH Meter Susu HI98162 Hanna Instruments, dirancang khusus pH Meter untuk industri milk / susu dengan Electrode berbahan dengan standard Food Grade. Tersedia berbagai macam alat laboratorium untuk berbagai macam kebutuhan.
Kami PT. Alfa Omega Indolab merupakan distributor produk Hanna Instruments, jual berbagai macam alat laboratorium yang sangat terpercaya dengan harga bersaing. Melayani pengiriman ke seluruh kota di Indonesia : Jakarta, Bandung, Semarang, Yogyakarta, Surabaya, Medan, Denpasar, Kupang, Makasar, Manado, Jayapura, Pontianak, Samarinda, Lampung, Jambi, dll. Temukan produk-produk kami yang lain untuk melengkapi kebutuhan Laboratorium Anda. Berikut beberapa alat ukur penting untuk uji kualitas air : pH Meter,TDS Meter,DO Meter,Photometer,COD Meter,Turbidity Meter,Conductivity Meter,Salinity Meter,ORP Meter,ISE Meter,Refractometer,Thermometer,Chemical Test Kit, dll. Hanna Instrument merupakan produsen alat-alat Laboratorium asal Italy yang fokus pada alat ukur untuk kualitas air.
The measurement of pH in milk is important in testing for impurities, spoilage, and signs of mastitis infection. While there are a number of factors that affect the composition of milk, pH measurements can help producers understand what might be causing certain compositional changes. pH measurement is commonly performed at various points in a milk processing plant.
Fresh milk has a pH value of 6.7. When the pH value of the milk falls below pH 6.7, it typically indicates spoilage by bacterial degradation. Bacteria from the family of Lactobacillaceae are lactic acid bacteria (LAB) responsible for the breakdown of the lactose in milk to form lactic acid. Eventually when the milk reaches an acidic enough pH, coagulation or curdling will occur along with the characteristic smell and taste of “sour” milk.
Milk with pH values higher than pH 6.7 potentially indicate that the milk may have come from cows with a mastitis infection. Mastitis is an ever-present challenge with dairy milking cows. When infected, the cow’s immune system releases histamine and other compounds in response to the infection. There is a resulting increase in permeability of endothelial and epithelial cell layers, allowing blood components to pass through a paracellular pathway. Since blood plasma is slightly alkaline, the resulting pH of milk will be higher than normal. Typically milk producers can perform a somatic cell count to detect a mastitis infection, but a pH measurement offers a quick way to screen for infection.
Understanding the pH of raw milk can also help producers optimize their processing techniques. For example, in operations that use Ultra High Temperature (UHT) processing, even small variations from pH 6.7 can affect the time required for pasteurization and the stability of the milk after treatment.
Measuring the pH of milk can provide a number of challenges. Milk products tend to have a high solids content that will coat the sensitive glass membrane surface and/or clog the reference junction. The FC1013 supplied with the HI98162 is specifically designed for measuring pH in milk. The Polyvinylidene fluoride (PVDF) body is a food grade plastic that is resistant to most chemicals and solvents, including sodium hypochlorite. It has high abrasion resistance, mechanical strength and resistance to ultraviolet and nuclear radiation. PVDF is also resistant to fungal growth. The FC1013 is an ideal general-purpose pH electrode for milk products that connects to the HI98162 with a quick-connect, waterproof DIN connector, allowing for a secure, non-threaded attachment.
This pH meter susu HI98162 meets the FDA Food Safety Modernization Act (FSMA) compliance standards.
The pH Meter Susu HI98162 uses the FC1013 amplified pH electrode with PVDF body. This specialized electrode offers numerous features that improve pH testing for milk producers. An integrated temperature sensor allows for temperature compensated pH measurements without the need for a separate temperature probe. The contact between the bulb’s large surface area and the milk sample ensures a stable calibration and measurement.
An integral part of any pH electrode is the reference junction. The reference junction is a part of the electrode that allows for the flow of ions located in the reference cell into the sample being tested. It is vital that this flow occurs in order to complete an electrical circuit, which ultimately determines the pH value. Any clogging of the junction will prevent completion of the circuit, resulting in readings that are erratic or constantly drifting.
The FC1013 probe utilizes a secondary reference chamber with ceramic outer junction allowing aqueous silver free electrolyte to flow slowly through the porous ceramic frit providing accurate readings for aqueous samples.
The durable PVDF body of the FC1013 ensures pH measurements can be safely taken on the dairy farm or production floor. The components of the electrode are also able to withstand a wider range of temperatures to allow for accuracy during stages such as pasteurization, which requires heating to temperatures near 72°C (161°F).
Besides being supplied with a unique milk pH electrode, the HI98162 has the Hanna’s unique CAL Check™ feature that alerts the user to potential problems during the calibration process. This is a very important for the milk processor since it is likely that the probe will be coated with the solids found in the milk being measured. This coating can easily lead to errors in pH measurement. By comparing previous calibration data to the current calibration, the meter will inform the user, with display prompts, when the probe needs to be cleaned, replaced, or if the pH buffer might be contaminated. After calibration, the overall probe condition is displayed on screen as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode, both of which can be found in the GLP data.
Pressing the “AutoHold” virtual key in measurement mode, the meter will freeze and automatically log a stable reading. An “out of calibration range” warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.
The log-on-demand mode allows the user to record and save up to 200 samples. The logged data, along with the associated GLP data, can then be recalled or transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software for traceability in record keeping for specific product batches. GLP data includes date, time, calibration buffers, offset, and slope, and is directly accessible by pressing the dedicated GLP key.
A contextual help menu based on the screen that is currently being viewed can be accessed at any time by the press of a dedicated button.
The high contrast, graphic LCD screen is easy to view outdoors in bright sunlight as well as in low-lit areas with the backlight. A combination of dedicated and virtual keys allows for easy, intuitive meter operation in a choice of languages.
The compact, durable HI720161 carrying case is thermoformed to hold all necessary components in milk pH Meter HI98162 for taking a field measurement, including the meter and electrode, beakers, buffer solutions and cleaning solutions.
Spesification of pH Meter Susu HI98162 Hanna Instruments :
Specification Name
Detail
sku
HI98162
pH Range
-2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH
pH Resolution
0.1 pH / 0.01 pH / 0.001 pH
pH Accuracy (@25°C/77°F)
±0.1 pH / ±0.01 pH / ±0.002 pH
pH Calibration
Up to five point calibration, seven standard buffers available (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and five custom buffers
mV Range
±2000.0 mV
mV Resolution
0.1 mV
mV Accuracy
±0.2 mV
Temperature Range
-20.0 to 120.0 °C (-4.0 to 248.0 °F)
Temperature Resolution
0.1 °C (0.1 °F)
Temperature Accuracy (@25°C/77°F)
±0.4 °C (±0.8 °F) (excluding probe error)
Temperature Compensation
Automatic
Log Feature
On demand, 200 samples (100 pH and 100 mV)
Connectivity
PC Connectivity opto-isolated USB
GLP
Yes
Power Supply
1.5V AA batteries (4 pcs.)
Power Consumption
approx. 200 hours of continuous use without backlight (50 hours with backlight)
Environment
4 to 50 °C (32 to 122 °F) max. RH 100% IP67
Dimensions
189 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight
404 g (14.2 oz)
Ordering Information
HI98162 is supplied with FC1013 PVDF body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700640 electrode cleaning solution for milk deposits sachet (2), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual with quick start guide, instrument quality certificate and HI720161 hard carrying case.
Warranty
2 years
Recommended Probe
FC1013 pre-amplified pH probe with internal temperature sensor, quick connect DIN connector and 1 m (3.3’) cable (included)
Portable Milk pH Meter HI98162 Hanna Instruments
Download Catalog :
The HI98162 is a rugged, waterproof, Foodcare portable pH meter that measures pH and temperature using the specialized FC1013 probe for milk products. This professional, waterproof meter complies with IP67 standards. The HI98162 is supplied with all necessary accessories to perform a pH/temperature measurement packaged into a durable thermoformed carrying case that holds the meters, probes and calibration buffers securely in place.
Deskripsi
Milk pH Meter HI98162 Hanna Instruments
pH Meter Susu HI98162 Hanna Instruments, dirancang khusus pH Meter untuk industri milk / susu dengan Electrode berbahan dengan standard Food Grade. Tersedia berbagai macam alat laboratorium untuk berbagai macam kebutuhan.
Kami PT. Alfa Omega Indolab merupakan distributor produk Hanna Instruments, jual berbagai macam alat laboratorium yang sangat terpercaya dengan harga bersaing. Melayani pengiriman ke seluruh kota di Indonesia : Jakarta, Bandung, Semarang, Yogyakarta, Surabaya, Medan, Denpasar, Kupang, Makasar, Manado, Jayapura, Pontianak, Samarinda, Lampung, Jambi, dll. Temukan produk-produk kami yang lain untuk melengkapi kebutuhan Laboratorium Anda. Berikut beberapa alat ukur penting untuk uji kualitas air : pH Meter, TDS Meter, DO Meter, Photometer, COD Meter, Turbidity Meter, Conductivity Meter, Salinity Meter, ORP Meter, ISE Meter, Refractometer, Thermometer, Chemical Test Kit, dll. Hanna Instrument merupakan produsen alat-alat Laboratorium asal Italy yang fokus pada alat ukur untuk kualitas air.
The measurement of pH in milk is important in testing for impurities, spoilage, and signs of mastitis infection. While there are a number of factors that affect the composition of milk, pH measurements can help producers understand what might be causing certain compositional changes. pH measurement is commonly performed at various points in a milk processing plant.
Fresh milk has a pH value of 6.7. When the pH value of the milk falls below pH 6.7, it typically indicates spoilage by bacterial degradation. Bacteria from the family of Lactobacillaceae are lactic acid bacteria (LAB) responsible for the breakdown of the lactose in milk to form lactic acid. Eventually when the milk reaches an acidic enough pH, coagulation or curdling will occur along with the characteristic smell and taste of “sour” milk.
Milk with pH values higher than pH 6.7 potentially indicate that the milk may have come from cows with a mastitis infection. Mastitis is an ever-present challenge with dairy milking cows. When infected, the cow’s immune system releases histamine and other compounds in response to the infection. There is a resulting increase in permeability of endothelial and epithelial cell layers, allowing blood components to pass through a paracellular pathway. Since blood plasma is slightly alkaline, the resulting pH of milk will be higher than normal. Typically milk producers can perform a somatic cell count to detect a mastitis infection, but a pH measurement offers a quick way to screen for infection.
Understanding the pH of raw milk can also help producers optimize their processing techniques. For example, in operations that use Ultra High Temperature (UHT) processing, even small variations from pH 6.7 can affect the time required for pasteurization and the stability of the milk after treatment.
Measuring the pH of milk can provide a number of challenges. Milk products tend to have a high solids content that will coat the sensitive glass membrane surface and/or clog the reference junction. The FC1013 supplied with the HI98162 is specifically designed for measuring pH in milk. The Polyvinylidene fluoride (PVDF) body is a food grade plastic that is resistant to most chemicals and solvents, including sodium hypochlorite. It has high abrasion resistance, mechanical strength and resistance to ultraviolet and nuclear radiation. PVDF is also resistant to fungal growth. The FC1013 is an ideal general-purpose pH electrode for milk products that connects to the HI98162 with a quick-connect, waterproof DIN connector, allowing for a secure, non-threaded attachment.
This pH meter susu HI98162 meets the FDA Food Safety Modernization Act (FSMA) compliance standards.
The pH Meter Susu HI98162 uses the FC1013 amplified pH electrode with PVDF body. This specialized electrode offers numerous features that improve pH testing for milk producers. An integrated temperature sensor allows for temperature compensated pH measurements without the need for a separate temperature probe. The contact between the bulb’s large surface area and the milk sample ensures a stable calibration and measurement.
An integral part of any pH electrode is the reference junction. The reference junction is a part of the electrode that allows for the flow of ions located in the reference cell into the sample being tested. It is vital that this flow occurs in order to complete an electrical circuit, which ultimately determines the pH value. Any clogging of the junction will prevent completion of the circuit, resulting in readings that are erratic or constantly drifting.
The FC1013 probe utilizes a secondary reference chamber with ceramic outer junction allowing aqueous silver free electrolyte to flow slowly through the porous ceramic frit providing accurate readings for aqueous samples.
The durable PVDF body of the FC1013 ensures pH measurements can be safely taken on the dairy farm or production floor. The components of the electrode are also able to withstand a wider range of temperatures to allow for accuracy during stages such as pasteurization, which requires heating to temperatures near 72°C (161°F).
Besides being supplied with a unique milk pH electrode, the HI98162 has the Hanna’s unique CAL Check™ feature that alerts the user to potential problems during the calibration process. This is a very important for the milk processor since it is likely that the probe will be coated with the solids found in the milk being measured. This coating can easily lead to errors in pH measurement. By comparing previous calibration data to the current calibration, the meter will inform the user, with display prompts, when the probe needs to be cleaned, replaced, or if the pH buffer might be contaminated. After calibration, the overall probe condition is displayed on screen as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode, both of which can be found in the GLP data.
Pressing the “AutoHold” virtual key in measurement mode, the meter will freeze and automatically log a stable reading. An “out of calibration range” warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.
The log-on-demand mode allows the user to record and save up to 200 samples. The logged data, along with the associated GLP data, can then be recalled or transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software for traceability in record keeping for specific product batches. GLP data includes date, time, calibration buffers, offset, and slope, and is directly accessible by pressing the dedicated GLP key.
A contextual help menu based on the screen that is currently being viewed can be accessed at any time by the press of a dedicated button.
The high contrast, graphic LCD screen is easy to view outdoors in bright sunlight as well as in low-lit areas with the backlight. A combination of dedicated and virtual keys allows for easy, intuitive meter operation in a choice of languages.
The compact, durable HI720161 carrying case is thermoformed to hold all necessary components in milk pH Meter HI98162 for taking a field measurement, including the meter and electrode, beakers, buffer solutions and cleaning solutions.
Spesification of pH Meter Susu HI98162 Hanna Instruments :
Produk Terkait
Two Channel pH/mV/ISE Meter HI5222 Hanna Instruments
pH/mV/ORP and EC/TDS/Salinity Meter HI5522 Hanna Instruments
Hydroponics pH Meter HI98115 Hanna Instruments