HI83314 Wastewater Multiparameter (with COD) Benchtop Photometer and pH Meter Hanna Instruments.
HI83314 Photometer Hanna Instruments is a compact, multiparameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available with an innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. 10 key water and wastewater quality parameters with 20 different methods covering multiple ranges are programmed into the meter. Wastewater treatment digestion parameters include COD, Total Nitrogen and Total Phosphorous which are important for monitoring nutrient removal. The HI83314 also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. To save valuable laboratory benchtop space, the HI83314 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.
Advanced optical system
Unparalleled performance from a benchtop photometer
Digital pH electrode input
Save valuable bench space with one meter that works both as a photometer and as a laboratory pH meter
Wastewater Treatment Digestion Parameters
Measures common wastewater parameters including COD, Total Nitrogen and Total Phosphorus
HI83314 benchtop photometer measures 10 different key wastewater quality parameters using 20 different methods that allow for multiple ranges and variations in chemistry for specific applications. The Chemical Oxygen Demand (COD) parameter is included for industrial and municipal wastewater treatment. The Phosphorous and Nitrogen parameters included are beneficial to municipal wastewater treatment customers that need to monitor their biological and chemical nutrient removal process. This photometer features an innovative optical system that uses LED’s, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time.
A digital pH electrode input is provided allowing the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.
Two USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.
The HI83314 offers an absorbance measuring mode that allows for CAL CheckTM standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the 4 wavelengths of light (420 nm, 466 nm, 525 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for education to teach the concept of absorbance by using the Beer-Lambert Law.
Features and Benefits
Digital pH Electrode Input
Measure pH and temperature with a single probe
Good Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability
pH CAL CheckTM alerts user to potential problems during the calibration process
Space saving having a pH meter and photometer built into one meter
Data Logging
Up to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button.
Sample ID and User ID information can be added to a logged reading using alphanumeric keypad
Connectivity
Logged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port
Data is exported as a .CSV file for use with common spreadsheet programs
Battery Status Indicator
Indicates the amount of battery life left
Error Messages
Photometric error messages include no cap, high zero, and standard too low
pH calibration messages include clean electrode, check buffer and check probe
Backlit 128 x 64 Pixel Graphic LCD Display
Backlit graphic display allows for easy viewing in low light conditions
The 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys and on-screen help to guide the user through use of the meter
Built-in Reaction Timer for Photometric Measurements
The measurement is taken after the countdown timer expires.
Countdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements
Absorbance mode
Hanna’s exclusive CAL CheckTM cuvettes for validation of light source and detector
Allows for the user to plot concentration versus absorbance for a specific wavelength for use with user supplied chemistry or for teaching principles of photometry
Units of Measure
Appropriate unit of measure along with chemical form is displayed along with reading
Result Conversion
Automatically convert readings to other chemical forms with the touch of a button
Cuvette Cover
Aids in preventing stray light from affecting measurements
Specification of Hi83314 Photometer Hanna Instruments :
Specification Name
Detail
sku
HI83314-01
Wavelength Accuracy
±1 nm
Light Source
5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters
Spectral bandwidth
8 nm
Input Channels
1 pH electrode input and 5 photometer wavelengths
pH Electrode
digital pH electrode (not included)
Logging Type
log on demand with user name and sample ID optional input
Logging Memory
1000 readings
Connectivity
USB-A host for flash drive; micro-USB-B for power and computer connectivity
GLP
calibration data for connected pH electrode
Display
128 x 64 pixel LCD with backlight
Battery Type / Life
3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement
Power Supply
5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
Environment
0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensing
Dimensions
206 x 177 x 97 mm (8.1 x 7.0 x 3.8″)
Weight
1.0 kg (2.2 lbs.)
Photometer/Colorimeter Light Detector
silicon photodetector
Cuvette Type
round, 24.6 mm
Number of Methods
128 max.
Ordering Information
Supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.
HI83314 Wastewater / COD Photometer Hanna Instruments
Download Catalog :
Deskripsi
HI83314 Wastewater Multiparameter (with COD) Benchtop Photometer and pH Meter Hanna Instruments.
HI83314 Photometer Hanna Instruments is a compact, multiparameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available with an innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. 10 key water and wastewater quality parameters with 20 different methods covering multiple ranges are programmed into the meter. Wastewater treatment digestion parameters include COD, Total Nitrogen and Total Phosphorous which are important for monitoring nutrient removal. The HI83314 also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. To save valuable laboratory benchtop space, the HI83314 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.
HI83314 benchtop photometer measures 10 different key wastewater quality parameters using 20 different methods that allow for multiple ranges and variations in chemistry for specific applications. The Chemical Oxygen Demand (COD) parameter is included for industrial and municipal wastewater treatment. The Phosphorous and Nitrogen parameters included are beneficial to municipal wastewater treatment customers that need to monitor their biological and chemical nutrient removal process. This photometer features an innovative optical system that uses LED’s, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time.
A digital pH electrode input is provided allowing the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.
Two USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.
The HI83314 offers an absorbance measuring mode that allows for CAL CheckTM standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the 4 wavelengths of light (420 nm, 466 nm, 525 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for education to teach the concept of absorbance by using the Beer-Lambert Law.
Features and Benefits
Digital pH Electrode Input
Data Logging
Connectivity
Battery Status Indicator
Error Messages
Backlit 128 x 64 Pixel Graphic LCD Display
Built-in Reaction Timer for Photometric Measurements
Absorbance mode
Units of Measure
Result Conversion
Cuvette Cover
Specification of Hi83314 Photometer Hanna Instruments :
Produk Terkait
Total Chlorine Ultra Low Range Photometer HI97761 Hanna Instruments
HI83308 Water Conditioning Photometer Hanna Instruments
HI83300 Photometer Hanna Instruments