Phenols Test Kit with Checker Disc HI3864 Hanna Instruments Hanna Instruments.
Phenol Chemical Test Kit HI3864 Hanna Instruments. The Phenols Test Kit HI3864 Hanna Instruments is a chemical test kit that uses the aminoantipyrine method to measure phenols in the low (LR) and high range (HR). The Phenols test Kit HI3864 is supplied complete with all of the reagents and equipment necessary to perform 100 tests.
All required materials are included with the test kit, such as the glass vials, reagent packets, and Checker® disc.
High resolution
Readings from 0.00 to 1.00 mg/L are determined to 0.02 mg/L resolution.
Readings from 0.5 to 5.0 mg/L are determined to 0.1 mg/L resolution.
Replacement reagents available
There is no need to buy a new kit when reagents are exhausted. The HI3864-100 reagent set can be ordered to replace the reagents supplied with the kit. This reagent set comes with 100 packets of HI3864A-0 and 100 packets of HI3864B-0.
Significance of Use
Phenols are widely used in pharmaceuticals, dyes and indicators, and as general disinfectants. They may occur in household and industrial wastewaters and in natural waters; they can also enter potable water supplies and chlorination of such waters results in malodorous chlorophenol products that are detectable from 0.001 mg/L (1ppb). The Hanna colorimetric method determines phenol and all ortho and para substituted phenols. Since substitution generally lowers the response, the readable value obtained by this method is the minimum concentration of phenolic compounds present. Natural water usually contains less than 0.001 mg/L of phenols, but sometimes values up to 0.02 mg/L (20 ppb) also occur. Since the concentration of phenols in wastewater is generally subjected to biological and chemical degradation, preserve samples in the refrigerator and analyze within four hours after collection.
Specification of HI3864 Phenol Chemical test Kit :
Specification Name
Detail
SKU
HI3864
Type
checker disc
Smallest Increment
0.02 mg/L (0.00 to 1.00 mg/L range) LR; 0.1 mg/L (0.5 to 5.0 mg/L range) HR
Method
aminoantipyrine
Ordering Information
HI3864 test kit comes with HI3864A-0 reagent (100 packets), HI3864B-0 reagent (100 packets), checker disc with LR and HR discs, glass vials with caps (2), and a mirror.
Reagent
HI3864-100
Phenol Range
0.00 to 1.00 mg/L (ppm) LR; 0.5 to 5.0 mg/L (ppm) HR
Phenols Test Kit with Checker Disc HI3864 Hanna Instruments
Download Catalog :
Deskripsi
Phenols Test Kit with Checker Disc HI3864 Hanna Instruments Hanna Instruments.
Phenol Chemical Test Kit HI3864 Hanna Instruments. The Phenols Test Kit HI3864 Hanna Instruments is a chemical test kit that uses the aminoantipyrine method to measure phenols in the low (LR) and high range (HR). The Phenols test Kit HI3864 is supplied complete with all of the reagents and equipment necessary to perform 100 tests.
Kami PT. Alfa Omega Indolab merupakan distributor untuk alat-alat Laboratorium. Kami menjual berbagai macam pH Meter Hanna Instrument dengan dukungan purna jual prima sehingga memberikan kenyaman kepada user. Melayani pengiriman ke seluruh kota di Indonesia. Temukan produk-produk kami yang lain untuk melengkapi kebutuhan Laboratorium Anda. Berikut beberapa alat ukur penting untuk uji kualitas air : pH Meter, TDS Meter, DO Meter, Photometer, COD Meter, Turbidity Meter, Conductivity Meter, Salinity Meter, ORP Meter, ISE Meter, Refractometer, Thermometer, Chemical Test Kit, dll. Hanna Instrument fokus memproduksi alat ukur kualitas air, sehingga sangat menjaga mutunya.
Features at-a-glance
Complete setup
High resolution
Replacement reagents available
Significance of Use
Phenols are widely used in pharmaceuticals, dyes and indicators, and as general disinfectants. They may occur in household and industrial wastewaters and in natural waters; they can also enter potable water supplies and chlorination of such waters results in malodorous chlorophenol products that are detectable from 0.001 mg/L (1ppb). The Hanna colorimetric method determines phenol and all ortho and para substituted phenols. Since substitution generally lowers the response, the readable value obtained by this method is the minimum concentration of phenolic compounds present. Natural water usually contains less than 0.001 mg/L of phenols, but sometimes values up to 0.02 mg/L (20 ppb) also occur. Since the concentration of phenols in wastewater is generally subjected to biological and chemical degradation, preserve samples in the refrigerator and analyze within four hours after collection.
Specification of HI3864 Phenol Chemical test Kit :
Produk Terkait
Backpack Lab Water Quality Educational Test Kit HI3817BP
Marine Test Kit HI3823 Hanna Instruments
Silica Chemical Test Kit HI38067 Hanna Instruments